| Port of Loading | Shanghai | Destination / Route | Middle East |
| Commodity | Forklift traction flooded lead-acid batteries | Compliance Code | UN2794 / Class 8 / P801 |
| Challenge | Client mistook flooded acid batteries for maintenance-free general cargo, high concealment risk | ||
| Solution | Classified UN2794, P801 leak & short-circuit packing, packaging certification, 45° tilt no-leak test | ||
A construction machinery parts exporter had a batch of forklift traction flooded lead-acid batteries to ship from Shanghai to the Middle East. Seeing the sealed-looking casing, the client assumed they were maintenance-free batteries and booked as general cargo. During our pre-loading review, we found the batteries actually had filler caps and contained free sulfuric acid electrolyte — a typical Class 8 corrosive dangerous good with high concealment risk.
Under IMDG Code 42-24 and GB 12268-2025 Dangerous Goods List:
We verified the spec and MSDS, confirming the batteries had filler caps and free sulfuric acid — flooded acid batteries — and defined them as UN2794 Class 8, explaining to the client that "sealed-looking casing" does not mean "maintenance-free".
Per P801, we used wooden pallets: insulating caps on each terminal, non-conductive corrugated separators between tiers, terminals not bearing weight, and shrink-wrap/strapping to prevent sliding, tipping, or impact.
Before loading, we ran the 45° tilt no-leak test on each pallet, confirmed no electrolyte spill, and checked for acid residue with moisture/corrosion protection on pallets.
We helped obtain the exit DG packaging use appraisal result (packaging certification), applied the Class 8 corrosive diamond (≥100mm) with "UN 2794", and corrected Section 14 of the MSDS.
With documents complete, we booked through the DG channel, completed the maritime declaration, and applied Class 8 placards per carrier requirements — accepted first try and loaded on schedule.
Check the form and the evidence: flooded batteries (with free acid/alkali) have no general-cargo pathway and must be declared UN2794/UN2795 Class 8. Only dry-charged batteries or sealed batteries passing the SP238 three tests may become non-DG — if it can be opened or there is no report, declare UN2794.
The following wet batteries are also declared Class 8 (UN2794/2795/2800). Each image is matched one-to-one with its commodity name:

Free sulfuric acid → UN2794; terminal insulation and 45° no-leak test required

Defaults to UN2800; SP238 three tests + short-circuit protection needed to become non-DG

Flooded form → UN2794; wooden pallet is the most common P801 packing

Classify by electrolyte: acid UN2794, alkali UN2795, sealed UN2800
Ginga Logistics provides wet-battery UN classification, P801/P003 packing, packaging certification, and leak & short-circuit pre-check — one stop.
Hunk Hu Mobile: +86-15692136029 Email: oversea22@gingalogistics.com