| Port of Loading | Shanghai | Destination / Route | Africa |
| Commodity | VRLA sealed maintenance-free batteries | Compliance Code | UN2800 / SP238 / IMDG 42-24 |
| Challenge | Client assumed sealed batteries auto-qualified as general cargo, but no SP238 test was done | ||
| Solution | Completed SP238 vibration/pressure-differential/55°C tests, obtained conformity declaration, shipped as non-DG | ||
An energy-storage equipment exporter had a batch of VRLA valve-regulated sealed maintenance-free batteries to ship from Shanghai to Africa. Seeing the "maintenance-free" and "sealed non-spillable" labels, the client assumed the batteries could ship as general cargo and booked directly. During our pre-loading review, we found the client had no SP238 test report or manufacturer conformity declaration — under the rules, "non-spillable" does not automatically mean non-DG.
Under IMDG Code 42-24 and GB 12268-2025 Dangerous Goods List:
We clarified that sealed batteries are exempt only after passing the SP238 three tests with short-circuit protection; without a report, they default to UN2800 Class 8. We worked out both cost paths to help the client decide.
We connected the client to a qualified third-party lab to complete the vibration, pressure-differential, and 55°C tests, obtaining the report confirming all three passed with no leakage and no free liquid.
We guided the client to issue the manufacturer conformity declaration, attaching the SP238 test report as the non-DG compliance basis.
Even as non-DG, we packed per short-circuit prevention: insulating caps on terminals, non-conductive separators between tiers, and secure fixation.
With documents complete, we booked as general cargo with the conformity declaration and test report on hand — accepted first try and loaded on schedule.
Sealed does not mean automatically non-DG. VRLA/AGM/gel batteries claiming non-spillable only satisfy the form check — they must pass all three SP238 tests with short-circuit protection to become non-DG. If it can be opened or there is no report, declare UN2800. Many clients trip on the word "maintenance-free", thinking they save on certification while actually creating a concealment risk.
The following sealed batteries are also assessed under UN2800 / SP238. Each image is matched one-to-one with its commodity name:

AGM/gel form; SP238 three tests + short-circuit protection needed to become non-DG

Sealed non-spillable → UN2800, P003+PP16 leak and short-circuit protection

Assess individually: flooded UN2794/2795, sealed UN2800, dry-charged non-DG

The only non-DG pathway is the SP238 three tests + conformity declaration
Ginga Logistics provides SP238 assessment, three-test guidance, conformity declaration and appraisal report connections, and short-circuit-proof packing — one stop.
Hunk Hu Mobile: +86-15692136029 Email: oversea22@gingalogistics.com